Also in: Español · اردو · हिन्दी · العربية

Solar water pump sizing calculator

Size a solar-powered pump for a borehole, well or river: how high it must push, how fast it must pump while the sun is up, how much power the pump draws, and how many panels it needs. Solar pumps usually fill a tank by day instead of using batteries.

m³/day

Livestock, irrigation or household use on a typical day of the dry season.

Volume unit
m

From the water level while pumping (not the well top) to the highest outlet or tank inlet.

Length unit
% of lift

10% suits short, well-sized pipe; use 20–30% for long or narrow runs.

h

For the season with the highest water need and least sun.

%

Wire-to-water.

Heat, dust, wiring.

W

Solar array for the pump

500 W

2 × 400 W panels

Total dynamic head
33.0 m
Average flow in sun hours
2.00 m³/h (33 L/min)
Pump input power
400 W (≈ 0.5 HP)
Lifting energy (water)
0.90 kWh/day
Electrical energy
2.00 kWh/day

How it works

  1. Total dynamic head (TDH). The height the pump works against: the vertical lift plus an allowance for friction in the pipe.

    TDH = vertical lift × (1 + friction% ÷ 100)

  2. Energy to lift the water. Lifting 1 m³ (1,000 kg) of water by 1 m takes 1000 × 9.81 J, or 0.002725 kWh. Put another way, 1 kWh lifts about 367 m³ by 1 m.

    Lifting energy (kWh/day) = m³/day × TDH × 0.002725

  3. Electrical energy. Pump, motor and controller waste part of the input.

    Electrical kWh = lifting kWh ÷ pump efficiency

  4. Pump power and flow. The pump runs on sunshine, so the day's water must be pumped in the sun hours.

    Flow (m³/h) = m³/day ÷ sun hours Pump input (W) = electrical Wh ÷ sun hours

  5. Array size. Panels deliver less than their rating in the field.

    Array W = pump input W ÷ array loss factor

The inputs

Water needed per day
For example, a dairy cow drinks around 50 to 100 L a day, a person 50 to 100 L for household use, and drip irrigation 2 to 5 L per m² per day in hot weather. Size for the driest, most demanding month.
Vertical lift
From the pumping water level (which falls below the resting level once pumping starts; ask the driller for the drawdown) up to the tank inlet or highest outlet.
Pipe friction allowance
Friction depends on pipe length, diameter and flow. 10% suits a short, generously sized pipe; long runs or narrow pipe can add 20 to 30% or more. A friction-loss chart for your pipe gives an exact figure.
Peak sun hours
For the season that matters, usually the dry season. "Estimate from my location" gives a yearly average by latitude.
Pump efficiency
Wire-to-water efficiency of the whole pump set. Small DC submersibles reach about 40 to 60%; AC pumps on a solar inverter often 30 to 45%.
Array loss factor
Share of rated panel power that reaches the pump. 0.8 allows for heat, dust and wiring.

Worked example

A farm needs 10 m³ of water a day from a borehole with a 30 m lift to the tank, a 10% friction allowance, 5 sun hours, a 45% efficient pump and 400 W panels.

  1. TDH: 30 × 1.1 = 33.0 m.
  2. Lifting energy: 10 × 33.0 × 0.002725 = 0.899 kWh a day.
  3. Electrical energy: 0.899 ÷ 0.45 = 2.00 kWh a day.
  4. Flow: 10 ÷ 5 = 2.0 m³/h; pump input: 1998 Wh ÷ 5 = 400 W.
  5. Array: 400 ÷ 0.8 = 500 W, so 2 × 400 W panels.

Look for a pump that delivers about 2.0 m³/h at 33 m head on its curve.

Assumptions and limits

  • Even pumping through the sun hours. Real solar pumps start slowly in the morning and peak at midday; a tank holding one to three days of water covers cloudy days.
  • Friction as a percentage of lift. This is a shortcut. Horizontal runs with little lift can have friction larger than the lift itself; work that out from a friction chart and add it to the lift.
  • No batteries. Pumping at night needs a battery bank and adds inverter losses.
  • Not checked: the pump's operating voltage and the array's string voltage, pipe size, well yield (the borehole must refill at least as fast as you pump), and pump start-up current.

Size the cable down the borehole with the wire size calculator, or convert between liters, gallons and flow units with the unit converter.

Take the design tools with you