Solar and electrical unit converter

Quick conversions for solar and electrical work: watts and horsepower, kWh and BTU, amp-hours and watt-hours, AWG and mm², feet and meters, gallons and liters, pump flow units, and °C and °F.

Power, energy, length, area, volume, flow

Wh
1,000
MWh
0.001
MJ
3.6
BTU
3,412.14
therm
0.034121

Amp-hours ↔ watt-hours

V
Ah
kWh
100 Ah at 12 V
1,200 Wh (1.2 kWh)
5 kWh at 12 V
416.667 Ah

AWG ↔ mm²

mm²
10 AWG
5.26 mm²
6 mm² is nearest to
9 AWG (6.63 mm²)

Nearest by size only. Standard metric and AWG sizes don't line up, so when swapping one for the other, pick the next size up and check its current rating.

Temperature

°F
77
K
298.15

How the conversions work

Each quantity converts through one base unit (W, Wh, m, m², L, L/min): the value is multiplied by its unit's factor to the base, then divided by the target unit's factor. A few conversions are formulas rather than factors:

Wh = Ah × V Ah = Wh ÷ V

°F = °C × 9/5 + 32 K = °C + 273.15

AWG diameter (mm) = 0.127 × 92^((36 − gauge) ÷ 39), area = π/4 × d²

The AWG formula is the standard definition (ASTM B258). For 1/0, 2/0, 3/0 and 4/0, use gauge numbers 0, −1, −2 and −3.

One more that trips people up: peak sun hours and kWh/m²/day are the same number. Sun maps that give daily irradiation in kWh/m² can be used directly as peak sun hours.

Worked examples

  • A 100 Ah, 12 V battery stores 100 × 12 = 1,200 Wh (1.2 kWh). A 100 Ah, 48 V battery stores four times as much: 4.8 kWh.
  • A 1 hp pump delivers about 746 W at the shaft (0.746 kW); the electrical power it draws is higher, because the motor is not 100% efficient.
  • A 10,000 BTU/h air conditioner moves 2.93 kW of heat. Its electrical draw is that divided by its efficiency (COP), often 0.8 to 1 kW.
  • 10 AWG wire is 5.26 mm²; the nearest metric sizes are 4 and 6 mm².
  • A 30 m cable run is 98.4 ft; 1,000 US gallons is 3.785 m³.
  • A panel datasheet's −10°C record low is 14°F; the 25°C test temperature is 77°F.

AWG to mm² table

AWGmm²
142.08
123.31
105.26
88.37
613.30
421.15
233.63
142.41
1/053.48
2/067.43
3/085.03
4/0107.22

Conversion factors used

Power
1 kW= 1,000 W
1 MW= 1,000,000 W
1 hp= 745.69987 W
1 BTU/h= 0.29307107 W
Energy
1 kWh= 1,000 Wh
1 MWh= 1,000,000 Wh
1 MJ= 277.77778 Wh
1 BTU= 0.29307107 Wh
1 therm= 29,307.107 Wh
Length
1 mm= 0.001 m
1 cm= 0.01 m
1 km= 1,000 m
1 in= 0.0254 m
1 ft= 0.3048 m
1 yd= 0.9144 m
1 mi= 1,609.344 m
Area
1 cm²= 0.0001 m²
1 ft²= 0.09290304 m²
1 in²= 0.00064516 m²
1 ha= 10,000 m²
1 acre= 4,046.8564 m²
Volume
1 m³= 1,000 L
1 US gal= 3.7854118 L
1 UK gal= 4.54609 L
1 ft³= 28.316847 L
Water flow
1 L/s= 60 L/min
1 m³/h= 16.666667 L/min
1 m³/day= 0.69444444 L/min
1 US gpm= 3.7854118 L/min

Sizing a cable rather than converting one? Use the wire size calculator. Turning Ah into backup time? Try the battery bank calculator.