Solar inverter size calculator

Two ways to size an inverter. For a grid-tied system, check the ratio of panel power to inverter power (DC/AC ratio). For an off-grid or backup system, size the inverter from the loads it must run and the surge when a motor starts.

System type
kW

Panel count × panel watts ÷ 1000.

kW

Rated continuous AC output from the inverter datasheet.

DC/AC ratio

1.20

Within the usual range: little energy is lost to clipping and the inverter is well used.

Inverter size for 1.1–1.3
4.6–5.5 kW AC
Array per kW of inverter
1.20 kW DC

How it works

Grid-tied: DC/AC ratio

Panels rarely produce their full rated power: heat, haze and sun angle keep them below it most of the time. So the inverter is usually a bit smaller than the array. The DC/AC ratio measures by how much:

DC/AC ratio = array kW (DC) ÷ inverter kW (AC)

A ratio of 1.1 to 1.3 is common. Above that, on the brightest hours the array can make more than the inverter can pass, and the excess is cut off (clipping). A little clipping is often worth it for a cheaper inverter that runs nearer its rating the rest of the day. The size range shown is:

Inverter kW = array kW ÷ 1.3 to array kW ÷ 1.1

Off-grid and backup: load and surge

An off-grid inverter must run everything that can be on at once, continuously, with margin:

Continuous rating ≥ peak load × 1.25

Motors (pumps, fridge and freezer compressors, air conditioners, power tools) draw several times their running power for a moment when they start. The inverter's surge rating must cover the other loads plus that start:

Surge rating ≥ peak load + largest motor × (surge factor − 1)

The inputs

Array size (DC)
Total panel wattage at standard test conditions, in kW.
Inverter rating (AC)
The rated continuous AC output, not the peak or maximum DC input.
Peak load
Add the running watts of every appliance that can be on at the same moment. A load audit helps.
Largest motor
The running watts of the single biggest motor load, already counted in the peak load. Only one motor is assumed to start at a time.
Surge factor
Starting power ÷ running power. 3× is a common rule; the appliance's locked-rotor current (LRA) or a clamp-meter reading gives a real value.

Worked examples

Grid-tied. A 6.6 kW array on a 5 kW inverter:

  1. Ratio: 6.6 ÷ 5 = 1.32, just above the 1.1–1.3 range.
  2. Inverter size for the range: 6.6 ÷ 1.3 = 5.08 kW to 6.6 ÷ 1.1 = 6.00 kW. Any inverter of 5.1 to 6.0 kW lands in the usual range.

Off-grid. Peak load 2,500 W, including a 700 W well pump, with a 3× starting surge:

  1. Continuous: 2,500 × 1.25 = 3,125 W.
  2. Surge: 2,500 + 700 × (3 − 1) = 3,900 W.
  3. Pick an inverter rated for at least 3,125 W continuous and 3,900 W surge; the next standard size up is the usual choice.

Assumptions and limits

  • The 1.1–1.3 band is a rule of thumb. The best ratio depends on climate, tilt, orientation and prices; east/west arrays and hot climates often suit higher ratios. Simulation tools can quantify clipping.
  • Not checked here: maximum DC input voltage and current per MPPT (see the string sizing calculator), the inverter's maximum DC power, and battery charge/discharge limits for hybrid inverters.
  • Inverter ratings fall in the heat. Many inverters derate above 40–45°C; leave extra margin in hot locations.
  • Surge duration varies. Inverters state surge power for a set time (often a few seconds); some motors need longer.

Common questions

What size inverter do I need for my solar panels?

For a grid-tied system, pick an inverter whose AC rating is the panel (DC) power divided by 1.1 to 1.3. A 6.6 kW array suits an inverter of about 5.1 to 6.0 kW. For off-grid, size from the loads instead: add up everything that can run at the same time, add 25%, and check that the surge rating covers motors starting.

Can I connect more solar panels than my inverter is rated for?

Usually yes, within the inverter maker's limits. A DC/AC ratio of 1.1 to 1.3 is common: the inverter clips a little power at sunny middays but produces more in the mornings, evenings and cloudy weather. 8 kW of panels on a 6 kW inverter is a ratio of 1.33, above the usual range, so expect more clipping. Always check the inverter's maximum DC input power and the string voltage.

What size inverter do I need to run a fridge?

A fridge compressor draws several times its running power for a moment when it starts. For a 150 W fridge plus 350 W of lights, TV and router, the calculator gives a continuous rating of at least 625 W and a surge rating of at least 800 W, assuming the motor starts at 3× its running power. Choose a model rated above both numbers.

Check the voltage side with the string sizing calculator, and size storage with the battery bank calculator.